Difference between revisions of "Light-O-Rama Controllers"

From DiyLightAnimation
Jump to: navigation, search
Line 12: Line 12:
  
 
* [http://diylightanimation.com/wiki/images/c/cd/Lor2Vix.zip Light-O-Rama v2 to Vixen sequence converter.]; written by aERonAUtical96 (Ron)
 
* [http://diylightanimation.com/wiki/images/c/cd/Lor2Vix.zip Light-O-Rama v2 to Vixen sequence converter.]; written by aERonAUtical96 (Ron)
 +
 +
Lynx Dongle to LOR 568b and possible D-light cable pinout
 +
 +
 +
[[Image:RJ45-Pinout.jpg]]
 +
 +
{|cellpadding="8" cellspacing="0"
 +
|Dongle
 +
|LOR
 +
|-
 +
|WH/OR  (1)
 +
|Blue (4)
 +
|-
 +
|Orange (2)
 +
|WH/Blue (5)
 +
|}
 +
 +
thanks to Joneslights for the information.
 +
 +
 +
This is a simple dongle to convert and crossover the blue and orange cable pairs.
 +
 +
It is just a RJ45 keystone jack on one end and TIa-568B plug on the other end.
 +
 +
[[Image:Lynx to LOR converter.jpg|400px]]
 +
 +
 +
[[Image:DLA-RJ45-wiring.jpg|600px|Thumb Drawing by tpctech]]
 +
*[[Media:Dla-rj45-wiring.pdf]] Drawing created by Tpctech
 +
  
 
Sample drawing of the Lynx Wireless system with a LOR controller
 
Sample drawing of the Lynx Wireless system with a LOR controller
Line 22: Line 52:
  
 
[[Category:Help|{{PAGENAME}}]]
 
[[Category:Help|{{PAGENAME}}]]
 +
[[Category:LOR]]

Revision as of 12:50, 29 April 2009

  • DMX-DOC.pdf; Light-O-Rama document showing firmware versions required for DMX operation
  • LOR controllers need to be updated to firmware v4.20 or higher to work in a DMX environment.
  • The only supported way to update the firmware in the LOR controllers is to use the LOR utility. This requires a valid licensed copy of of the Light-O-Rama sequencing software.
  •  ? Question: Is the LOR controller auto terminated?

Lynx Dongle to LOR 568b and possible D-light cable pinout


RJ45-Pinout.jpg

Dongle LOR
WH/OR (1) Blue (4)
Orange (2) WH/Blue (5)

thanks to Joneslights for the information.


This is a simple dongle to convert and crossover the blue and orange cable pairs.

It is just a RJ45 keystone jack on one end and TIa-568B plug on the other end.

Lynx to LOR converter.jpg


Thumb Drawing by tpctech


Sample drawing of the Lynx Wireless system with a LOR controller

Wireless-Lynx-Lor.jpg