Step 1 - '''Turn off power to controller and move jumper to program mode'''
 
Step 1 - '''Turn off power to controller and move jumper to program mode'''
  
Step 2 - '''Run RJ's Lynx Address Program and select address you need. Click on Program button''' [http://diylightanimation.com/index.php?action=dlattach;topic=2742.0;attach=2887 Click here to download if needed, Lynx Address Utility]
+
Step 2 - '''Run RJ's Lynx Address Program and select address you need. Click on Program button''' [http://diylightanimation.com/index.php?action=dlattach;topic=2676.0;attach=2607 Click here to download if needed, Lynx Address Utility]
  
 
Step 3 - '''Turn on controller and count to 5'''
 
Step 3 - '''Turn on controller and count to 5'''

Revision as of 17:06, 30 May 2011

To program the Lynx Controller/Dimmer.

Step 1 - Turn off power to controller and move jumper to program mode

Step 2 - Run RJ's Lynx Address Program and select address you need. Click on Program button Click here to download if needed, Lynx Address Utility

Step 3 - Turn on controller and count to 5

Step 4 - Turn off controller and move jumper back to operation mode

Step 5 - Click Stop on the Lynx Address Program

Step 6 - Turn on controller and use your selected program to see if controller is now on the correct start address.

Either exit Lynx Address Program or go back to step 1 to program another controller

OPTIONAL Way if the above doesn't work - From RJ

Step 1 - Start with the SSR4.

Step 2 - Turn it on and using my address utility start it sending the address you want out.

Step 3 - With the SSR4 still powered carefully move the jumper.

Step 4 - Count to 3 seconds.

Step 5 - pull the plug on the SSR4.

Step 6 - put the jumper back to operate and power it back up.